Illumination / Uniformity / Brightness / Black Level
To measure uniformity we define a matrix with 15 measuring points. The point in the center defines 100% brightness and based on that we calculate deviation in percent. Luminance is measured with brightness sett to its maximum. The black level on the other hand is measured with the brightness set to the minimum. To measure the brightness, we're using a Voltcraft LX-1108. The contrast ratio can be determined by dividing brightness by black level.
White |
348 cd/m2 |
368 cd/m2 |
379 cd/m2 |
390 cd/m2 |
357 cd/m2 |
375 cd/m2 |
414 cd/m2 |
449 cd/m2 |
444 cd/m2 |
393 cd/m2 |
372 cd/m2 |
391 cd/m2 |
383 cd/m2 |
397 cd/m2 |
369 cd/m2 |
|
- 29.02 % |
- 22.01 % |
- 18.47 % |
- 15.13 % |
- 25.77 % |
- 19.73 % |
- 8.54 % |
0.00 % |
- 1.13 % |
- 14.25 % |
- 20.70 % |
- 14.83 % |
- 17.23 % |
- 13.10 % |
- 21.68 % |
Black |
0.25 cd/m2 |
0.24 cd/m2 |
0.27 cd/m2 |
0.33 cd/m2 |
0.26 cd/m2 |
0.33 cd/m2 |
0.28 cd/m2 |
0.43 cd/m2 |
0.45 cd/m2 |
0.33 cd/m2 |
0.29 cd/m2 |
0.27 cd/m2 |
0.34 cd/m2 |
0.41 cd/m2 |
0.36 cd/m2 |
|
- 72.00 % |
- 79.17 % |
- 59.26 % |
- 30.30 % |
- 65.38 % |
- 30.30 % |
- 53.57 % |
0.00 % |
+ 4.65 % |
- 30.30 % |
- 48.28 % |
- 59.26 % |
- 26.47 % |
- 4.88 % |
- 19.44 % |
Uniformity of the VA panel used for the SE790C is average. In the center, this panel is notably brighter than on the edges. On the outside deviation in percent doesn't surpass 15%. If we include the three measurement points in the center we see a maximum deviation of 29.02%, which is visual to the human eye.
Brightness / Contrast / Black Level |
Brightness Average |
389 cd/m2 |
Brightness Maximum |
449 cd/m2 |
Brightness Minimum |
56 cd/m2 |
Contrast Ratio |
1215:1 |
Black Level |
0.32 cd/m2 |